ZFS achieved 22 credits for LEED certification through:

Site Selection

  • Didn’t meet any of the prohibited criteria

Alternative Transportation

  • Bike rack
  • Reserved parking spots for alternative fuel vehicles and carpooling vehicles

Reduced Site Disturbance

  • Open space exceeds local zoning requirements by 25 percent
  • Reserved parking spots for alternative fuel vehicles and carpooling vehicles

Storm Water Management

  • Post-development 1.5 year, 24-hour peak discharge rate and quantity don’t exceed pre-development conditions
  • Storm water treatment has at least an 80 percent reduction in total suspended solids and a 40 percent reduction in total phosphorus

Water Efficient Landscaping

  • Potable water consumption for irrigation has been reduced by at least 50 percent through high efficiency irrigation technology and the use of drought-tolerant and native plants

Ozone Protection

  • Heating, ventilating, air conditioning and cooling (HVAC) systems don’t contain hydrochlorofluorocarbons (HCFSs) or halons

Recycled Content

  • Recycled scrap materials during construction
  • Project achieved a combined recycled content value of 30.68 percent of the total materials by cost, compared to the 45 percent default value
  • Received an innovation credit
  • Used recycled products in construction
  • 45.48 percent of the building’s materials were manufactured using raw materials harvested within 500 miles of the project site

Local/Regional Materials

  • 84.95 percent of the building’s materials were manufactured within 500 miles of the project site
  • Received an innovation credit

Certified Wood

  • 51.28 percent of wood materials are certified

Indoor Air Quality Management Plan

  • Followed and implemented an indoor air quality plan
  • Installed filters with a MERV (Minimum Efficiency Reporting Value) 13 rating
  • Used heating, ventilating and air conditioning during construction
  • Conducted a two-week building flush with 100 percent outside air

Low-Emitting Materials

  • Use low-emitting adhesives and sealants
  • Carpeting complies with the Carpet Rug Institute (CRI) Green Label Program

Thermal Comfort

  • Installed temperature and humidity control ranges to maintain indoor comfort
  • Installed a permanent temperature and humidity monitoring system that operates during all seasons
  • Designed to provide feedback that will allow operators to maintain thermal comfort

LEED Accredited Professional

  • Had an environmental advisor/Green Building consultant serve as a principal participant of

leedaward

LEED Certification

With energy and the environment in mind, ZFS’ new administration building was designed to meet silver certification for LEED (Leadership in Energy and Environmental Design) The LEED office, with its improved technology, increases ZFS’ efficiency and provides room for future growth.

With energy and the environment in mind, ZFS’ new administration building was designed to meet silver certification for LEED (Leadership in Energy and Environmental Design) The LEED office, with its improved technology, increases ZFS’ efficiency and provides room for future growth.